Arrived on site for maintenance. Checked evaporator coils of air handler in basement.
Arrived onsite for heating maintenance 1 gas fired furnace. Turn heat on and confirmed operation. Brushed and Wiped down furnace blower cabinet and gas burners. Burners fired and are in good working order. Observed noise from combustion exhaust system. Measured 1.3 amps which is within specification but motor has used over 90% of its life. No visual impingement detected. Checked electrical. Measured .9 amps on the hot surface ignitor. Measured 63 degree heat rise. Cleaned the flame sensor. System is operating as it should. Due age and condition of furnace, recommend updating the system. Homeowner noted only the indoor coil is new; the outdoor AC condenser is older and due for replacement as well.
Having trouble with your home's cooling system? Contact Climate Plus LLC for a prompt service. Joe spoke with the professional, who will arrive soon to fix the issue. Remember to call before heading to the location.
10-1 Arrival; EPP 1C- Seasonal Maintenance. Customer will provide filter
8-9 AM Arrival; Comfort Club 1C AC Start up. System was installed last July. No notes on filters that I can see. Install does say "Ran 10 ft. Of duct with 5 10 inch takeoffs." not sure if that helps us find filter size. Customer is aware of cost of services. Customer mentioned that they sent paperwork for permit to us and we never completed it. I sent a message to Joe about it day we scheduled.
Performed Heating maintenance on Amana Gas Fired Furnace